loading

 ICP Sensor is a weather sensor manufacturer and environmental monitoring solution provider with 15+ years of industry experience.

ICP Sensors par meter solution provider 1
ICP Sensors par meter solution provider 1

ICP Sensors par meter solution provider

Payment:
T/T, L/C or Paypal
OEM/ODM:
Available
MOQ:
2 PCS
Model:
RK200-03
Lead Time:
5-7 days
Certification:
CE-EMC, CE-LVD, RoHS, ISO9001
Inquiry

PRODUCT DESCRIPTION

The rk200-03 Pyranometer is produced based thermopile principle; sensing elements are made by winding - plated thermopiles with multi contacts.Its surface is coated by black coating with high absorption rate. Hot contacts on the sensors surface, while the cold junction is located within the body,temperature difference between the hot and cold junction generates electromotive force, the thermoelectric effect is proportional to the solar radiation. In order to reduce the ambient temperature effect ,temperature compensation circuit designed here to reduce the effects to products properties.

ICP Sensors par meter solution provider 2

SPECIFICATIONS

Item

Specification

Spectral range

300-3200nm

Supply

5V,12-24VDC

Range

0-2000W/m2

Output

0-20mV,0-5V,4-20mA,RS485

Sensitivity>

7-14μV*W-1*m2

Internal resistance

350Ω

Non-linearity

<±2%< p="">

Measuring angle

2π solid angle

Response time

≤20s(99%)

Zero drift( temperature drift:5k/h)

±5W/m2

Stability

±2%/year

Cosine correction

≤±7%(Solar elevation angle=10°)

Temperature effect

±2%(-10℃-+40℃)

Operating temperature

-40℃-+80℃

Recalibration interval

2 years

Desiccant

Silica gel desiccant

Weight(unpacked)

2.5kg

Pack

Aluminum alloy instrument box

Dimension

?185*120mm

Installation bracket(optional)

Horizontal bracket or adjustable angle bracket

Ingress Protection

IP65

Storage Condition

10℃-60℃@20%-90%RH

DIMENSION

ICP Sensors par meter solution provider 9
ICP Sensors par meter solution provider 10

OUTPUT CHARACTERISTICS

 0-20mV

Solar radiation values(W/m2)= Voltage output value(μV)/sensitivity coefficient(μV*W-1*m2),

Each product is with one sensitivity coefficient respectively  (It is mentioned on the product’s label)

 0-5V

Solar radiation values(W/m2)=(V/5)*2000(Where V is output voltage value, unit:V )

 4-20 mA

Solar radiation values(W/m2)=((I-4)/16)*2000(Where I is output current value,unit:mA )

 RS485

MODBUS-RTU

MOUNTING & MAINTENANCE

 The sensor should be installed in the open air without any shield above the sensing surface.

 The sensor connector should be faced to the north, fix it after the horizontal position is well adjusted.

 Please check the filter cover regularly & make sure it is clean.

 Please do not remove or loose the filter cover,otherwise the accuracy will be affected.

 Please make sure the desiccant to be dry .(If the color of desiccant is changed from blue to red or white,  it should be replaced,it is recommended to replace the desiccant every 6 month.)

 Protection cover is not necessary in general rainfall, but if prolonged heavy rains or hail,  the protective cover is recommended to be installed.

The sensitivity is recommended to be re-calibrated after two years use.

PRODUCT DETAILS

ICP Sensors par meter solution provider 11

ICP Sensors par meter solution provider 12Product Principle

ICP Sensors par meter solution provider 13

ICP Sensors par meter solution provider 14 Double-Glass With Cosine Correction

ICP Sensors par meter solution provider 15

ICP Sensors par meter solution provider 16Horizontal Installation

ICP Sensors par meter solution provider 17

ICP Sensors par meter solution provider 18Desiccant Part & Portable Carry Case

PRODUCT APPLICATION

                                                                         

Contact us
we welcome custom designs and ideas and is able to cater to the specific requirements. for more information, please visit the website or contact us directly with questions or inquiries.
no data
RIKA Sensor
Copyright ? 2026 Shenzhen ICPS Technology Co., Ltd. | Sitemap | Privacy Policy  
Customer service
detect